NDW3-4000 Offshore Wind Power
NDW3-4000 Offshore Wind Power Air Circuit Breaker (hereinafter referred to as the circuit breaker), suitable for AC 50/60Hz power distribution networks with rated currents from 800A to 4000A, rated insulation voltage AC1250V, and rated operating voltages of AC220/230/240V, AC380/400/415V, AC440/480V, AC660/690V, AC800V, AC1000V, and AC1140V. It is
-
NDW3AGZ-2500
NDW3AGZ-2500 DC Disconnect Switch For Distribution Networks With Rated Currents Of 1600~2500A, Rated Maximum Working Voltage Of DC1500V, And Rated Nominal Working Voltage Of DC1250V, Used For Making And Breaking The Main Circuit And Providing Isolation.
-
NDW3A-2500
The NDW3A-2500 (UL) air circuit breaker is designed for AC 50/60Hz power distribution networks with a rated current of 1000~2000A, rated insulation voltage of 1250V, and rated operating voltages of AC254V, AC508V, AC635V, and AC730V. It distributes electrical energy and protects circuits and power equipment from overload, undervoltage, short circui
-
NDW3Z
NDW3Z-2500/4000 DC-Type Air Circuit Breaker For DC, Rated Current 800A~4000A, Rated Insulation Voltage DC1500V, Rated Operating Voltage DC500V/750V, DC1000V/1500V
-
NDW3
The NDW3 Series Air Circuit Breaker (hereinafter referred to as the breaker) is designed for power distribution networks with AC 50Hz/60Hz, rated current from 200A to 7500A, rated insulation voltage of 1000/1250V, and rated operating voltages of AC220V/230V/240V, AC380V/400V/415V, AC440V/480V, AC660V/690V, AC800V, AC1000V, AC1140V, AC1380V, and AC1
-
NDW2G
Suitable for AC/DC systems, primarily installed in low-voltage distribution circuits for making and breaking the main circuit and providing isolation. Rated operational current: 400A~4000A, rated operational voltage: up to AC690V and up to DC1500V.
-
NDW2
The NDW2 Series Universal Circuit Breaker Is Designed For Power Distribution Networks Operating At AC 50Hz/60Hz, With A Rated Current Range Of 200A To 6300A, Rated Insulation Voltage Of 1250V, And Rated Working Voltages Of AC220V/230V/240V, AC380V/400V/415V, AC440V/480V, And AC660V/690V. The NDW2-4000 And NDW2-6300 Models Are Also Applicable In Net
Need Help?
-
Contact Customer Service
Providing Comprehensive Professional Consulting Services Including Solution Recommendation, Configuration Selection, Technical Guidance, and Complaint Assistance
Go there now -
Frequently Asked Questions
Here You Can Find Professional Consulting Services Including Product Operation Guides, Solution Configurations, And Frequently Asked Questions
Go there now -
Anti-Counterfeiting Verification
Official Anti-Counterfeiting Verification Portal, Standardized Inquiry Process, Accurate Product Authenticity Validation, Protecting Consumer Rights
Go there now